S200-MF
FEATURES
S200-MF is a new-generation spectrometer with high spectral and spatial resolution across the entire area of commercially available 2D (array) image sensors.IDEAL ASTIGMATISM COMPENSATION ACROSS THE ENTIRE FOCAL PLANE;
SYNCHRONOUS SPECTRA IMAGING FROM TWO UP TO DOZENS OPTICAL FIBERS;
INTEGRATED CCD-ARRAY AND CUSTOM SOFTWARE FOR MULTI- CHANNEL OPTICAL SPECTROSCOPY;
EMBEDDED MECHANICAL SHUTTER SYNCHRONIZED WITH THE DETECTOR FOR PROCESSING CONTINUOUS SIGNALS;
PERFECT SYSTEM FOR HYPERSPECTRAL IMAGING.
DESCRIPTION
S200-MF is a new-generation spectrometer with high spectral and spatial resolution across the entire area of commercially available 2D (array) image sensors.
Due to innovative optical bench and specially designed optics with aberration correction the S200-MF spectrometer features complete compensation of astigmatism both in the center of detector’s sensitive area and at its edges. This allows connecting a multi-fiber optical bundle to the entrance slit of the spectrometer and acquiring spectra from several fibers simultaneously. Maximum number of optical fibers in the bundle depends on the height of sensor area and on fiber diameter. When using standard sensors as large as 6 mm tall a number of simultaneously analyzed fibers may reach several dozens.
S200-MF has a fixed entrance slit and can operate either with optical fibers, or without them. At direct input of radiation into the spectrometer an image from the analyzed area is projected directly on the entrance slit, and the detector acquires spectral information from this area with high spatial resolution.
The S200-MF spectrometer ensures perfect flat field and high image quality at any point at the center of the detector and at its edges. Compact size and short-focal-length optical bench of S200-MF allow synchronous imaging of the wide spectral range which is limited only by the detector spectral sensitivity.
SPECIFICATIONS
SPECTROMETER MODEL | S200-MF |
Spectral range | 200÷1100 nm |
Focal length | 191 mm |
Aperture ratio | 1 : 8.5 |
Entrance slit (one to choose) | Fixed width: 20, 30, 50 or 100 µm |
Spectral resolution | Depends on selected diffraction grating (see table below) |
CCD-detector model | S10140-1109 |
Number of pixels | 2068 x 512 |
Number of active pixels | 2048 x 506 |
Pixel size | 12 x 12 µm |
Active area size | 24.576 x 6.072 mm |
Maximum spectral response | 600 nm |
Maximum quantum efficiency | >90 % |
Non-uniformity of spectral response (1) | ±3 % |
Anti-blooming (2) | Yes |
ADC | 16 bit, 250 kHz |
Mean-square reading noise, ADC counts | < 12 |
Dynamic range | ~ 5 400 : 1 |
Exposure time | 8,3 ms — 3 s (3) |
Frame processing time in the binning mode | 9,39 ms |
TE cooling | No |
Operating temperature | 10÷30 0Ñ |
Computer interface | Full Speed USB |
Synchronization | IN/OUT |
Requirements to External sync pulse: | |
polarity | positive |
amplitude | 3-15 V |
FWHM | 5-20 µs |
sync connector | BNC-58 |
Triggering pulse parameters: | |
polarity | positive |
amplitude | 3-5 V |
FWHM | 10 µs |
Mechanical shutter (for operation with continuous signals, option) | |
open/close time | < 15 ms |
min. time between openings | 80 ms |
Optical input | multicore optical fiber (fiber specification is to be agreed on) |
without fiber | |
Dimensions, weight | 283 x 129 x 123 mm, 4.4 kg |
1) signal level — 50% of saturation.
2) anti-blooming – sensor feature eliminating overflow of charges from the over-exposed pixels to the neighboring ones.
3) maximum storage time is deemed to be the time at which dark signal makes up 10% of the dynamic range at the ambient temperature +250Ñ.
RECOMMENDATIONS FOR CHOOSING A DIFFRACTION GRATING
At the time of placing your order you should choose grating grooves density (i.e. spectral resolution of your instrument), as well as the spectral range for operation.
For your convenience the table below lists the average values of grating dispersion, spectral resolution and multichannel array bandpass. Contact a Solar LS specialist for getting more precise parameters of your spectrometer.
DIFFRACTION GRATINGS, LMM | 200 | 300 | 400 | 600 |
max spectral range, nm | 200 – 1100 nm | |||
multichannel array bandpass (average), nm | 600 | 400 | 300 | 200 |
reciprocal linear dispersion (average), nm/mm | 25.3 | 16.8 | 12.7 | 8.4 |
spectral resolution (average), nm* | 1.2 | 0.9 | 0.6 | 0.45 |
*Spectral resolution is indicated for the entrance slit 20 µm wide.
EXAMPLE: If you are interested in 400-700nm spectral range (300nm multichannel array bandpass), you may choose 400lmm diffraction grating and get the average spectral resolution of 0.6nm.
Overall dimension of the S200-MF Spectrometer.
OPTIONS & ACCESSORIES
Applications for spectrometers with multi-fiber input nowadays include spectrophotometry, plasma physics, biology, etc. A range of applications constantly expands.
Thus, with S200-MF you can record synchronously not a single spectrum as traditional spectrometers do, but two, five, ten, twenty or more spectra in accordance with requirements of your application.
S200-MF: Deuterium lamp spectra acquired with 21-fiber bundle prove high spectral resolution (image above) and spatial resolution (image below).
S200-MF can also be used to get spectral images from a linear section of sample in an optical microscope. When moving the analyzed object in the microscope with XY scanning stage 2D-hyperspectral images can be acquired.
SOLARLS的所有資訊來自SOLARLS網頁,所有版權歸SOLARLS,繁體字版權屬安均科技。