Model SHR-IR
FEATURES
The SHR-IR spectrometer is an ideal instrument for measuring absolute wavelength value of pulse and CW lasers and diodes in the spectral range from 600nm to 1800nm with accuracy better than ± 15pm, as well as detecting FWHM of the analyzed line.
SPECTRAL RANGE FROM 600NM TO 1800NM.
ACCURACY BETTER THAN ± 15PM.
SPECTRUM & FWHM ANALYSIS.
COMPACT DESIGN; NO MOVING COMPONENTS.
OPTICAL FIBER INPUT; DIFFUSE ATTENUATOR.
IDEAL FOR MEASURING WAVELENGTH OF PULSED AND CW LASERS.
DESCRIPTION
Apart from wavelength measuring the SHR-IR provides demonstration of analysed spectra with resolution of 4 000 (λ/Δλ, FWHM) which constitutes from 0.15nm for 600nm to 0.5nm for 1800nm. The SHR-IR also ensures on-line monitoring of the above values in the process of tuning the analysed wavelength.
The instrument does not contain any moving elements; powering and control are performed from a computer via the Full-Speed USB interface. Analysed light is steered to the entrance slit either via a multimode optical fiber with a diffuse attenuator (included in the delivery set) or directly, without any fibers.
In respect of resolution and wavelength measuring precision the SHR-NIR is an alternative to a monochromator-spectrograph with focal length not less than 500mm, equipped with an appropriate IR-detector.
But unlike the monochromator, the SHR-NIR has no moving elements and provides real-time measurements without scanning. The SHR-IR is rigid, stable and accurate, ensures absolute reliability and has more reasonable price.
The SHR-NIR spectrometer is indispensable in the process of adjustment, alignment and testing of laser systems operating in the near IR spectrum range.
SPECIFICATIONS
OPTION | VALUE |
Operation mode | CW and pulsed light (externally triggered) |
Spectral range, nm | 600-1800 |
Accuracy of wavelength detection, nm | ± 0.015 |
Resolution (l/DlFWHM) | 4 000 (ΔλFWHM from 0.15nm for 600nm to 0.48nm for 1800nm) |
Source linewidth requirements, not more than | ≤125 cm-1 (from 4nm for 600nm to 40nm for 1800nm) |
Optical interface |
|
Computer interface | Full Speed USB interface |
Requirements to external trigger pulse (for pulsed lasers) | |
— polarity | Positive |
— amplitude, V | 3-15 |
— pulse duration FWHM, μs | 5-20 |
— rise time, μs | ~10 |
— connector | BNC-58 |
Software | WLMeter |
Dimensions, mm | 142 x 110 x 80 |
Weight, kg | 1.2 |
SPECTRA
Optical parametric oscillator (OPO). Idler wave. Real-time measurements at tuning laser wavelength.
1725-1750nm laser diode spectrum acquired with the SHR-IR.