1. Description
HID TEMPerHUM thermometer & hygrometer is a measurement device using USB port to connect to a computer . It can measure the temperature and the humidity of the machine and the environment accurately and can calculate the dewpoint automatable. It must be connect to the computer to start working .HID TEMPerHUM can be use in computer room, weather, environment and special environment temperature and humidity testing.
2. Function & Feature
- Range of temperature: TEMPerHUM -40~+85 ºC; -40~+185ºF;
- Resolution rate of temperature: 0.06 ºC
- Temperature sensor :
(1) +/- 0.5ºC accuracy (Typical)
(2) +/-1ºC accuracy (Maximum @ 0 to 70 ºC) - Range of humidity:0~100RH%
- Resolution rate of humidity:0.03RH%;
- Precision of humidity: +/- 3 RH% (20RH%~80 RH%)
- Voltage: 4~6V;
- Electricity:< 10 mA;
- Voltage : 5V
- Support Windows NT,XP, VIST,Windows 7,10
- Memory requirement: 20M
- Data autosave to be txt or csv format, can be open by excel;
- Send mails function
- Graph transfer function
(1)TXT Special button:
As long as you long pressing the TXT button for 1 seconds, you can read the temperature and humidity no matter in excel, text or word form without running software. If to stop the reading, press the TXT button again . Easy operation! Solve your installed software and cross-platform used troubles!
(2) Caps lock and Num Lock:
3.How to validate if your mobile phone is in line with the OTG?
A: Use OTG line connecting a mouse or keyboard, see if the mouse is normally used in conformity with the OTG.
4. INSTALLING INSTRUCTION
Software download link:http://pcsensor.en.made-in-china.com
a) Install framework , if your computer system is Vista, may be you don’t need to install this process. Dotnetfx.exe is framework 2.0 of Microsoft; you can download it from the website of Microsoft;
b) Download the TEMPer v26.5 and install ,then run it.
5. Operating instruction
(Note: Our software just only support windows system .)
a) when the Alarm is on, it will send the Email to Specified Email Box Automatically if the Temperature or humidity Reach the Alarm Limit.
b) You can set the Sending Interval, and then it will send the Email to the Specified Mail Box at Set Intervals. (Advise)
c) it can Send Email Continuously to the Specified Mail Box. (Deprecated feature)
4) Data Remote
you can view the data remote in other computer after you log in the registering account.
5) General Setting
a) Readd interval-Language-Temp unit -Software shutdown mode
b)Calibration
c)Alert setting
d)File save
e)Voice Alert